当前产品special transformer ratio tester, transformer ratio test system, transformer ratio tester HB-BZ2000

special transformer ratio tester, transformer ratio test system, transformer ratio tester HB-BZ2000

参考价面议
具体成交价以合同协议为准
  • 公司名称青岛华至宝电气有限公司
  • 品       牌
  • 型       号
  • 所  在  地青岛市
  • 厂商性质其他
  • 更新时间2025/4/10 7:50:58
  • 访问次数
在线询价收藏产品 点击查看电话

联系我们时请说明是 兴旺宝 上看到的信息,谢谢!

产品详情

special transformer ratio tester, transformer ratio test system, transformer ratio tester HB-BZ2000


产品简介

Scott transformer ratio test system, special transformer ratio tester, transformer ratio test system, transformer ratio tester, transformer ratio group tester
Transformer ratio tester for railway, transformer ratio testing system for metro, transformer ratio tester for locomotive
The portable hb-bz2000 transformer transformation ratio test system recommended by the Ministry of electric power adopts a single-chip microcomputer to control large-scale color LCD screen to display man-machine dialogue, automatically measure the wiring group, automatically change the polarity, and automatically switch the phase sequence range. It meets the tests of Z-type transformer, rectifier transformer, electric furnace transformer, non integral point phase shift transformer, traction transformer, Scott and inverse Scott transformer. It is a recommended product for electric power.
Hb-bz2000, hand micro 186+5322+5978, qq1123+134968
1. Single phase power input, digital synthetic three-phase test power output (distortion less than 0.1%, symmetry better than 0.05%), the test results have better equivalence, and there will be no group misjudgment and other phenomena.
2. Single phase and three-phase can automatically measure polarity, phase angle, variable ratio, error, tapping position, tapping value and other parameters, and can automatically identify the group number.
3. Accurately measure the phase angle between the high and low voltage sides, and measure the transformation ratio and angle of the transformer with non integral points.
4. The test results are displayed in digital and hexagonal vector diagram, and the connection group of transformer can be seen visually.
5. There is no need to select the wiring mode and wiring group. There is no need for external short circuit for measuring y/ △, △ /y transformers. The wiring mode can be automatically switched according to the selected test content. It is completely possible to measure the transformation ratio and group number of transformers without nameplate.
6. It can quickly measure the transformation ratio and transformation ratio error at each tapping switch position. The transformation ratio error at each tapping position can be calculated by inputting the rated transformation ratio only once.
7. At the same time, it has two functions: turn ratio measurement and operation voltage transformation ratio measurement. The operation transformation ratio can more truly reflect the actual value of the voltage transformation ratio under the actual operation of the transformer.
8. Meet the testing of various power transformers, Z-type transformers, rectifier transformers, electric furnace transformers, non integral point phase shift transformers, traction transformers, Scott and inverse Scott transformers
9. The 5.6-inch high-definition true color LCD screen is used to display the data effect and the vector image effect.
10. The test source used in this instrument is a standard sinusoidal digital source with digital synthesis, and the distortion is less than 0.1%, which is not affected by the quality of the working power supply.
11. Military products have small size, light weight and strong anti-interference ability.  
12. The high-capacity lithium-ion rechargeable battery can complete the test work on site without any power supply, and more than 800 consecutive measurements can be carried out at one time.
Supply: Railway specific transformer ratio tester Scott transformer ratio tester inverse Scott transformer ratio tester special transformer ratio tester transformer ratio test system transformer ratio tester transformer ratio group tester Metro specific transformer ratio test system locomotive transformer ratio tester
For details, please visit: or or Query.
Solemnly declare: Qingdao Huabao Electric has no branch or distribution office, and no relatives in this business. Those similar or similar units or individuals have nothing to do with our company. Please identify the brand of Huabao (HB) when purchasing, and contact our company directly to prevent counterfeiting. For details, please consult the hotline 186+5322+5978.


免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,兴旺宝网对此不承担任何保证责任。

发布询价单

青岛华至宝电气有限公司

型:
其他
联系人:

联系我时,请说明是在兴旺宝上看到的,谢谢

商家概况

主营产品:
变压器试验设备
公司性质:
其他

该商家其它产品

Double clamp grounding resistance tester HB-ST

Double clamp gro...

摘要:Doubleclampgroundingresis [详细]
Constant speed device, constant speed source, constant speed device, megger verification, speed d...

Constant speed d...

摘要:Constantspeeddevice [详细]
DC resistance tester, HB-ZRZ

DC resistance te...

摘要:DCresistancetester,HB-ZRZ [详细]
Intelligent large current generator,HB-ZL

Intelligent larg...

摘要:Intelligentlargecurrentge [详细]
Transformer comprehensive test instrument,HB-VA2008

Transformer comp...

摘要:Transformercomprehensivet [详细]
Transformer ratio group tester,HB-BZ

Transformer rati...

摘要:Transformerratiogrouptest [详细]
Automatic analyzer acid value,HB-SKS

Automatic analyz...

摘要:Automaticanalyzeracidvalu [详细]
Single phase relay protection tester,HB-7

Single phase rel...

摘要:Singlephaserelayprotectio [详细]

对比栏